Sizing a Standby Generator What Size Generator Does My House Need?

How a standby generator is sized for a house: the load calculation, whole house or selected circuits, and how load management lets a smaller unit do the job.

By Adam Zell of Boston Automations · Updated

The short answer

The right size comes from a load calculation, not square footage. It adds up what you want to run, and especially the large motors that start at the same time, such as air conditioners and well pumps.

For most homes the answer is an air-cooled unit, and load management often lets a smaller generator carry the whole house.

How is a standby generator sized?

A standby generator is sized by a load calculation. The electrical code is specific about this. Under the 2023 National Electrical Code, which Massachusetts uses, a generator on an automatic transfer switch has to carry everything the switch connects to it, unless a load management system limits the load to what the generator can supply.

So the question is what the switch will connect and whether something manages it. On the site visit we look at the panel, the nameplates on the large equipment and how you use the house, then size the generator to that.

What drives the size up?

Large motors matter most, because they draw several times their running power for a moment when they start. Central air conditioning, heat pumps, well pumps and sump pumps are the usual ones. Electric ranges, dryers, water heaters and EV chargers add a lot of steady load. Lights, electronics and a gas furnace's blower add very little.

How manufacturers describe home generator sizes
SizeWhat Kohler says it covers
10 to 14 kWThe basics: furnace fan, refrigerator, sump pump, lights and well pump
20 kWMost major appliances
26 kWThe entire home
48 kWEverything in a home with 200 amp service

Kohler's own descriptions, October 2026. Your load calculation decides.

How does load management change the size?

Load management lets a smaller generator do a bigger job. A controller watches the generator and switches large loads on and off so they never all start together. Generac's 200 amp service-rated transfer switch manages up to four air conditioners with no extra hardware, and its Smart Management Modules handle more. Kohler offers PowerBoost to start large loads without dropping the rest of the house, and a load shed kit.

Many whole-house air-cooled systems work this way, and it is the main way to keep the cost down. See what a standby generator costs.

Whole house or selected circuits?

A whole-house transfer switch moves the entire panel onto the generator, so everything works in an outage and nobody has to remember which outlets are live. A switch for selected circuits backs up only the ones you choose, such as heat, the refrigerator, the well pump and a few lights, and it pairs with a smaller generator.

For very large homes that want everything on at once, a liquid-cooled generator is the answer. If parts of the house cannot tolerate even the seconds it takes a generator to start, look at a RoseWater system in front of it.

Frequently asked questions

What size generator do I need for a 3,000 square foot house?

What size generator do I need for a 3,000 square foot house?

Square footage alone doesn't decide it. Two 3,000 square foot houses can need very different generators depending on central air, electric appliances, a well pump and what you want running. A load calculation on the site visit gives the real number.

Will a 22 kW generator run a whole house?

Will a 22 kW generator run a whole house?

Often, yes, with load management. A 22 kW air-cooled generator paired with a transfer switch that manages air conditioning and other large loads can carry many whole houses. Without load management the generator has to cover everything that might start at once.

What is load management?

What is load management?

A controller that watches the generator and switches large loads such as air conditioners, a dryer or an EV charger on and off so the generator is never overloaded. Generac's 200 A transfer switch manages up to four air conditioners without extra hardware, and Kohler offers PowerBoost and a load shed kit.

Should I back up the whole house or only some circuits?

Should I back up the whole house or only some circuits?

Whole house is simpler to live with, because everything works in an outage. Selected circuits cost less and suit a smaller generator. We lay out both on the quote so you can choose.

Does the fuel change the size I need?

Does the fuel change the size I need?

A little. Air-cooled generators make less power on natural gas than on propane. Generac's 24 kW unit is rated 24 kW on propane and 21 kW on natural gas, so on natural gas you size to the lower number.