RoseWater Energy
Custom 208 V three-phase power systems for the largest homes, estates and buildings.
What is a RoseWater 3-phase system?

Best for
- Homes and estates on a 208 V three-phase service
- Mixed-use and small commercial buildings
- Projects with large mechanical or AV loads
What you get
- Three sizes: 30, 45 and 75 kVA across three legs
- 12 to 30 hot-swappable 2.5 kVA inverter modules
- Batteries sized to the target run time, not a fixed shelf count
- Cordex controller with Ethernet/SNMP, a web interface and a touchscreen
- Surge and lightning protection rated for up to 40 strikes of 140,000 V
RoseWater 3-Phase Systems specifications
| Service | 208 V three-phase |
|---|---|
| Hub3P30 | 30 kVA (10 kVA per leg) |
| Hub3P45 | 45 kVA (15 kVA per leg) |
| Hub3P75 | 75 kVA (25 kVA per leg) |
| Inverter modules | 12 to 30, hot-swappable |
| Module rating | 2.5 kVA / 2.0 kW each |
| Battery | Sized to the run time the project needs |
|---|---|
| Battery chemistry | Advanced lead-acid (carbon) |
| Surge rating | Up to 40 strikes of 140,000 V |
|---|---|
| Solar input | Up to 10 kW with the SBX10 |
| Controller | Cordex, with Ethernet/SNMP, web interface and touchscreen |
| Remote monitoring | Built in |
| Enclosure | Electronics cabinet and battery cabinet, side by side |
|---|---|
| UPS cabinet | 84" H x 28.1" W x 26.25" D |
| Room | Climate-controlled, -20°C to 40°C ambient |
| Warranty | 3 years from commissioning |
Specifications as published by RoseWater Energy on rosewaterenergy.com. Run time depends on what the system carries, so we calculate it in your Power Plan rather than quote a number here.
How is a 3-phase system sized?
Share the drawings
Single-line diagram, riser diagrams and panel schedules from your electrician or electrical engineer.
Set the loads
We agree which panels and circuits the system carries, and how long it needs to run on battery.
Engineer with RoseWater
RoseWater's engineers confirm the model, module count and battery bank before anything is ordered.
The Power Plan walks through the same load categories RoseWater uses, so we start your design with real information.
Who installs it?
Boston Automations
Builds your Power Plan, designs and specifies the system, registers the project with RoseWater's engineering team, coordinates the electrician, programs and integrates the HUB with your home's systems, and supports it for the life of the system.
Your licensed electrician
Makes the electrical tie-in at your panel. If you have an electrician you trust, we work with them. If you do not, we bring in one we know.
RoseWater Energy
Builds the HUB, delivers it to the install location, and sends an on-site technician to commission it. Commissioning by RoseWater-trained personnel is what starts the three-year warranty.
RoseWater 3-Phase Systems questions
Which RoseWater systems work on a 208 V three-phase service?
Which RoseWater systems work on a 208 V three-phase service?
The Hub3P30, Hub3P45 and Hub3P75 are built for 208 V three-phase service, at 10, 15 and 25 kVA per leg. The HUB20 and HUB40 can also accept two legs of a 208 V three-phase service when that suits the loads.
How big is a RoseWater 3-phase system?
How big is a RoseWater 3-phase system?
The UPS cabinet is 84 inches high, 28.1 inches wide and 26.25 inches deep. The battery cabinet stands beside it, and its size depends on how much storage the project needs.
Where does a 3-phase system need to go?
Where does a 3-phase system need to go?
It needs a climate-controlled room. RoseWater specifies an ambient range of -20°C to 40°C for the 3-phase system, so we plan the mechanical room with your builder or engineer early.
What information do you need to size a 3-phase system?
What information do you need to size a 3-phase system?
We need the electrical single-line diagram, the riser diagrams and the panel schedules. With those, RoseWater's engineers and our team can confirm the model and the battery bank.
Where to go next
Build Your Power Plan
Choose what should stay on and get a first sizing for your home.
How a HUB works
Diagrams that show how the HUB handles surges, sags, noise and an outage.
Backup Power for a Custom Home
For builders, architects and electricians: timing, room space, drawings and the budget line.
Whole House Power Conditioning
What dirty power is, why lights flicker and equipment reboots, and how conditioning at the panel fixes it.
Lead-Acid vs Lithium Home Batteries
Safety, life span, indoor rules and recycling, and why RoseWater chose advanced lead-acid.
Backup power FAQ
Straight answers on batteries, generators, solar and installation.
Talk to us
Call (781) 333-8003 or send a note and we will set up a consultation.
Planning a 208 V Home or Building?
Send us the drawings or start a Power Plan. We will work with your engineer and RoseWater to size the right 3-phase system.